our Cummins gas power generator best-in-class, high-efficiency, low-emission gas engines and gen sets are designed for various applications such as power generation, cogeneration, and waste to energy. These Cummins gas generators are suitable for a broad range of commercial, industrial and municipal uses with long service intervals, easy maintenance and low fuel consumption.
Altronic Ignition Systems are state-of-the-art systems engineered to provide:
A robust, reliable and fuel flexible power generation
Mechanical power output: from 30 to 600 kWb (1,200, 1,500 and 1,800 rpm)
Powered by natural gas, landfill and sewage gas, flare and well gas, syngas
Proven reliable and robust design
Fast start availability
Fuel flexibility
Fuel blending availability
Eco friendly
Cost efficient implementation and service
Load acceptance great flexibility
Best in class global efficiency
Model | FYC30G | FYC40G | FYC50G | FYC85G | FYC125G | FYC150G | FYC230G | FYC300G | FYC500G |
---|---|---|---|---|---|---|---|---|---|
Prime Power/kW | 30 | 40 | 50 | 85 | 125 | 150 | 230 | 300 | 500 |
Standby Power/kW | 33 | 45 | 55 | 94 | 138 | 165 | 250 | 330 | 550 |
COP K/w | 24 | 32 | 40 | 68 | 100 | 120 | 180 | 238 | 396 |
Rated speed/rpm | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
long block engine Brand | Cummins | Cummins | Cummins | Cummins | Cummins | Cummins | Cummins | Cummins | Cummins |
Genset Steady Rate | <1% | <1% | <1% | <1% | <1% | <1% | <1% | <1% | <1% |
Engine Model | PC4B | PC4BTAA | PC6B | PC6BTAA | PC6CTAA | PC6LTAA | PC6NTAA | PC6KTAA | PC12KTAA |
Prime power | 33 | 45 | 55 | 94 | 138 | 165 | 250 | 330 | 550 |
Intake Mode | Natural Aspiration | Turbocharged and Air Cooled | Natural Aspiration | Turbocharged and Air Cooled | Turbocharged and Air Cooled | Turbocharged and Air Cooled | Turbocharged and Air Cooled | Turbocharged and Air Cooled | Turbocharged and Air Cooled |
No.of cylinders | 4 | 4 | 6 | 6 | 6 | 6 | 6 | 6 | 12 |
Bore | 102 | 102 | 102 | 102 | 114 | 114 | 140 | 159 | 159 |
Stroke | 120 | 120 | 120 | 120 | 135 | 145 | 152 | 159 | 159 |
Compression Ratio | 11.5:1 | 11.5:1 | 11.5:1 | 11.5:1 | 11.5:1 | 11.5:1 | 10.5:1 | 10.5:1 | 10.5:1 |
Displacement | 3.9 | 3.9 | 5.9 | 5.9 | 8.3 | 8.9 | 14 | 18.9 | 37.8 |
Speed Governing | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical | Electrical |
Starting Method | 24V Electric Start | 24V Electric Start | 24V Electric Start | 24V Electric Start | 24V Electric Start | 24V Electric Start | 24V Electric Start | 24V Electric Start | 24V Electric Start |
Lube Specification | 15WCH_40 | 15WCH_40 | 15WCH_40 | 15WCH_40 | 15WCH_40 | 15WCH_40 | 15WCH_40 | 15WCH_40 | 15WCH_40 |
Lube Capacity | 10.9 | 10.9 | 16.4 | 16.4 | 23.8 | 27.8 | 40 | 50 | 134 |
Gas consumption | 0.32 | 0.32 | 0.32 | 0.32 | 0.32 | 0.32 | 0.32 | 0.32 | 0.32 |
Alternator Specification | |||||||||
Brand | Stamford | Stamford | Stamford | Stamford | Stamford | Stamford | Stamford | Stamford | Stamford |
Voltage | 380-415 | 380-415 | 380-415 | 380-415 | 380-415 | 380-415 | 380-415 | 380-415 | 380-415 |
Power/kW | 30 | 40 | 58 | 96 | 128 | 160 | 200 | 300 | 500 |
Speed/rpm | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
Phase | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Power Factor | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
Steady Voltage Regulation | ±1.5% | ±1.5% | ±1.5% | ±1.5% | ±1.5% | ±1.5% | ±1.5% | ±1.5% | ±1.5% |